The head weight of any hammer used shall not exceed 3 pounds. Type I, Front Loader A family of mail receptacles in a single column configuration with a single master door design, a minimum of 3 and a maximum of 8 customer compartments, 1 mail collection compartment with separate outgoing mail slot and Arrow lock door, and 1 parcel compartment. Dissimilar metals shall be protected against galvanic corrosion. However, no offered outgoing mail compartment height shall preclude any of the critical installation requirements, or any other requirement, from being met. 4.3 Operational Requirements The carrier access (Arrow lock) door, customer doors, parcel doors, master loading door(s), and hold open device(s) must be capable of operating 10,000 normal operating cycles (1 cycle = open/close) at room temperature, continuously and correctly, without any failures such as breakage of parts. 1. 4.11.8 Rear Door/Panel (Rear Loading Designs only) The rear cover shall be tested for a period not to exceed 3 minutes by attempting to force it to unseat. 3.8.1 Front-Loading Designs For front-loading designs, the front of the minimum-sized collection compartment shall consist of the carrier access (Arrow lock) door, as described in section 3.5.3, and the mail collection/deposit slot, which is framed by separate elements providing the weather and security shielding. $65.00. Total Package Value $ This package has a dimension measuring over 12". After the release of the load, the permanent deformation caused by the forces shall be measured. A 3-pound hammer shall be used for a time period not to exceed 1 minute in tandem with these other tools during the tests of the seams and gaps around the perimeter of this item. Postal Service Arrow Lock, key keepers may also be converted to locks appropriate for private uses so others on your staff can gain access to controlled areas.. Manufacturers may be subject to a verification of their quality system prior to approval. Prior to the test, the unit shall be prepared by shielding the body of the receptacle so that only the master door, customer doors, and front frame elements shall be directly exposed to rain during the test. The gauge must be capable of easy insertion and removal, and while inserted, allow for the door(s) to be completely closed without interference. In addition, the USPS may, at its discretion, order that production of the receptacle cease immediately, and that any existing inventory not be sold or used for receipt of U.S. mail. In addition, no compartment size shall be offered that is larger than any fully tested size. 4.4 Water-Tightness A rain test in accordance with UL 771, section 47.7 shall be performed to determine a receptacle’s ability to protect mail from water. All multi unit constructions building plans submitted after October 6, 2006 are required to use STD-4C … Numbers shall be made with one decal and not a combination of two single letter or number decals. The receptacles shall be designed and constructed so that they can be serviced according to the intended method, front or rear access. Hi, Use arrow key to access related widget. The Arrow lock and the 910 lock shall be located in a partitioned compartment and, for ease of maintenance reasons, shall not share the same compartment cover. The master loading doors shall be easily unlatched and opened using one hand. If the USPS rescinds approval, the manufacturer is not prohibited from applying for a new approval pursuant to the provisions of section 6. The USPS has the right to evaluate the acceptability and effectiveness of the approved source’s quality management system prior to approval, and during tenure as an approved source. Any proposed changes shall be submitted with the affected documentation reflecting the changes (including a notation in the revision area), and a written explanation of the changes. As a minimum, the quality management system shall include controls and record keeping in the following areas: This package isn't a standard, rectangular box. Type V, Rear Loader A family of mail receptacles in a double column configuration with a rear access cover design, a minimum of 3 and a maximum of 16 customer compartments, 1 mail collection compartment, and 1 or 2 parcel compartments. For rear-loading designs, these inscriptions must be centered on the blank panel of the outgoing mail compartment. may be used in the fabrication of the receptacle, providing it produces a satisfactory and safe joint and is performed in accordance with applicable best commercial practices. At the conclusion of the test, the outside of the unit is wiped dry and all doors are opened. 4.1 Testing Requirements Units will be subjected to all applicable testing described herein. Arrow offers a full line of key system products from cylindrical to rim and mortise cylinders. Weight. The door hinges shall be concealed or designed to prevent tampering. If other versions of the approved Type unit are to be offered, the drawings must include the unique or differing design items of these versions. Any front doors of customer compartments in alignment with the cables may be opened or removed for the test. 6.1.3.3 Certification of Compliance & Test Results Manufacturers shall furnish a written certificate of compliance indicating that their design fully complies with the requirements of this standard. The Arrow lock and the 910 lock shall be located in a partitioned compartment and, for ease of maintenance reasons, shall not share the same compartment cover. I've never laid eyes on a USPS arrow key, I'd love to get a working lock and key into my collection (that's unlikely to ever happen though). 7.1 Disapproval Written notification, including reasons for disapproval, will be sent to the manufacturer within 30 days of completion of the final review of all submitted units. You can't. The receptacle's mounting hardware will be subjected to a uniform pull load of 500 pounds. Welding, riveting, and other joining shall be done in a neat and approved manner. Each unit shall be made of the exact materials, construction, coating, finish, etc., as shown on the manufacturer’s drawings, which are identified and certified by the Postal ServiceTM. 5.3.5 Control of Inspection, Measuring, and Test Equipment The approved source shall ensure that all equipment used to verify product conformance is controlled, identified, and calibrated at prescribed intervals traceable to nationally recognized standards in accordance with documented procedures. Sheet metal screws shall not be used in the assembly of the receptacle. You can't. The maximum combined length and girth for USPS Retail Ground is 130". Figure 10 Front Loader, Parcel Only (No Master Door) - Long Description 3.7.2 Parcel Compartment Sizes The minimum interior dimensions of the parcel compartments shall be as follows: Username and password must be entered. In the vertical direction, the customer lock and the numbers shall be the same centerline. Build a custom direct mail campaign by taking advantage of extras and add-ons offered by USPS® and many third-party websites. 7.2.2.5 Final USPS Rescission Notification The USPS shall provide a final response to the manufacturer in writing no later than 30 calendar days after receipt of the second sample corrected receptacle with a determination of whether the manufacturer’s submission is accepted or rejected and with specific reasons for the determination. The use of this standard is mandatory and the receptacles shall conform to this standard in order to be approved by the Postal ServiceTM. The test gauge will be inserted with a 14-15/16 inch dimension aligned on the vertical axis (perpendicular to the compartment floor). Custom Cards & Stationery. 4.11.5 Arrow Lock Compartment Door (Front Loading Designs only) The Arrow lock compartment door shall be tested using the pry tools in 4.11 for a period not to exceed 3 minutes. 6.1.3 Final Review Manufacturers shall submit two representative samples of the largest (typically, the highest total-compartment) version to the USPS for security testing, final review and approval. No pry tools shall exceed 18 inches in length. with card insert (side A & B). All bolster plate cables will be tied together at a minimum distance of 3 feet from the front surface of the unit with a single cable fitted with a shackle, hook, etc. 4.11.3 Parcel Compartment Door Gaps and seams around the perimeter of the parcel compartment door(s) shall be tested using pry tools listed in 4.11 for a period not to exceed 3 minutes to ensure that access to the compartment cannot be gained. Figure 13. Share Mail uses direct mail to create social networking style word-of-mouth recommendations. 7.2.2. Arrow Keys- the APO must maintain all arrow keys for the APO and RMPO. Send Mail & Packages Convenient Domestic Shipping. All correspondence and inquiries shall be directed to the address listed in 1.3. Want to save time and ship from home? It's sad that some of the USPS info on these locks has dried up. (b)Large Parcel Locker 18 inches high by 12 inches wide x 15 inches deep. 4.11.1 Customer Compartment and Parcel Compartment Customer Access Locks Customer lock plugs shall withstand a minimum of 70 pounds of force slowly applied inward. If the deformation exceeds the limit specified in table II, the unit under test has failed to meet the structural rigidity requirement. In addition, Arrow has also introduced a new cam lock product to expand this line. In this case, the locking pin(s) shall secure the Arrow lock door to the master loading door frame. Additionally, the drawings must fully describe any purchased materials, components, and hardware including their respective finishes. No part of the receptacle may show finish corrosion, blistering, or peeling, or other destructive reaction upon conclusion of test. Type III, Front Loader A family of mail receptacles in a double column configuration with a single master door design, a minimum of 3 and a maximum of 16 customer compartments, 1 mail collection compartment with separate outgoing mail slot and Arrow lock door, and 1 or 2 parcel compartments. The master loading door(s) shall allow access to all the unit’s customer compartments and parcel compartments for the deposit of letter mail and parcels and the collection of customer outgoing mail. The hole shall be able to withstand 100 foot pounds of rotational torque, preventing the lock from being turned in the door allowing unauthorized entry into the compartment. The spring shall be of sufficient strength to close the door from any opened position. Width in. Each door shall permit the mounting of locks as required by 3.10.2. The maximum package weight permitted by USPS is 70 lbs. Username. Moving announcements can tell new customers you are in the neighborhood, let current customers know your new address, or let friends and family know you've moved. Material requirements and specifications are clearly described in procurement documents. Before I got my uniform authorization, I had the arrow key chain attached to the belt loop of my jeans. In addition, the Arrow lock compartment door will also be subjected to a 2-minute torch test using commonly available microtorch kits. They may be engraved or stamped. Residents on San Francisco's Nob Hill are at risk for identity theft after a USPS master key slipped into the wrong hands. and they really don’t give them out. 8403 LEE HIGHWAY Custom photo cards let friends and family know and remember your life events—moves, weddings, births, graduations, and more. Type IX, Rear Loader (No Parcel Compartment) A family of mail receptacles in a double column configuration with a rear access cover design, a minimum of 3 and a maximum of 19 customer compartments, and 1 mail collection compartment. 3.8 Collection Mail and Carrier Access (front-loading designs only) Compartment All units shall have one reinforced collection mail compartment. 3.5 Customer and Parcel Compartment Doors All compartment doors shall meet the common requirements listed in this section. Arrow timeline template. 7.2.1 Approved Receptacles Units that are approved will be retained by the USPS. Mounting Hole, PSIN 0910 Customer Lock - Long Description, Note: Additional test laboratories may be added provided they satisfy USPS certification criteria. The 910 lock cover shall be secured with standard hardware while the Arrow lock compartment cover shall be secured with tamper resistant screws. Florence Key keepers are designed to securely provide access to important keys to only those authorized to use them. Figure 7 Rear Loader, Single Column (No Parcel Compartment) - Long Description The mail deposit slot frame design shall be hard mounted to the master door structure. In the vertical direction, the customer lock and the numbers shall be the same centerline. The Arrow lock shall be furnished and installed by the local postmaster or his representative. One unit, incorporating the changes, may be required to be resubmitted for testing and evaluation for approval. Alternatively, each compartment may be equipped with either a clasp or holder to accommodate a name card, or supplied with a designated flat surface for a permanent-type pressure-sensitive label for identifying the customer using the compartment. With our vertically integrated ISO certified manufacturing facilities, you can rely on Salsbury Industries to manufacture your Surface Mounted Key Keeper for USPS Access with expertise. 5.3.4 Control of Nonconforming Product The control method and disposition process shall be defined and ensure that any product or material that does not conform to the approved design is identified and controlled to prevent its unintended use or delivery. Those keys are tightly controlled and the postal service knows exactly how many are out there and where they are. 3.10.3 Master Loading Door Lock (Front-Loading Designs) Front loader receptacles shall be secured with an Arrow lock, in accordance with figure 13, to lock the master loading door(s) as defined in section 3.6.1. This multi-color, modern timeline design template is highly effective as a business plan template, or even as a project timeline, highlighting milestones or goals progressively, from idea to success, as emphasized by the arrow pointing upwards. The preliminary review consists of a review of the manufacturer's conceptual design drawings for each receptacle type for which the manufacturer is seeking approval. Register / Sign In Use arrow key to access related widget. The ASTM D3801 standard flame test shall achieve a rating of V-1 or better. Inspection by the USPS does not relieve the approved source of the responsibility to provide conforming product. Click to get the latest Buzzing content. Test Evaluation & Quality A limited loading shall be permitted on the end of the Arrow lock bolt only when the Arrow lock is used as an actuator to engage locking pins. In addition, Arrow has also introduced a new cam lock product to expand this line. MERRIFIELD VA 22082-8101. The receptacle design shall preclude access from one compartment to another and it shall provide the required level of security for all receptacle contents and resistance to vandalism. 7.2.3.1 Corporate or Organizational Changes If any substantive part of the approved manufacturer’s structure changes from what existed when the manufacturer became approved, the manufacturer shall promptly notify the USPS and will be subject to a reevaluation of their approved product(s) and/or quality system. 6.1.3.1 Installation Instructions Manufacturers shall furnish a written copy of their installation instructions for review. If the second submission is rejected, the USPS may, at its discretion, rescind approval of the receptacle. Customer Service. Receptacles submitted to the USPS (see 1.3) for final evaluation must be identical in every way to the receptacles to be marketed, and must be marked as specified in 3.11. Rescission Manufacturer’s production units shall be constructed in accordance with the USPS-certified drawings and the provisions of this specification and be of the same materials, construction, coating, workmanship, finish, etc., as the approved units. Heavy-duty rings for attaching the holder to the individual key shall be provided for parcel receptacle keys. The design of all wall-mounted, centralized mail receptacles may be of the Types specified in 1.2. TABLE II (Note: For any nonparcel compartment design, disregard parcel compartment references.). The door hold-open device shall withstand an inward or outward pull of 50 (+5, -0) pounds when applied to the master door edge farthest from the master door hinge and in a direction perpendicular to the door. 3.4 Mounting and Hardware The hardware for attaching the receptacle to the wall shall be provided and packaged with the unit. 3.7.2.1 Parcel Locker to Customer Compartment Ratio A minimum of one standard parcel locker shall be provided for every ten customer compartments. The locks shall be oriented so that the locking cam rotates 90 degrees from the locked to the unlocked position. The cover or door shall prevent the mail from falling out between the cover or door and shelves, and be strong enough to prevent theft of the contents of adjoining receptacles by manually forcing the rear door or cover from the front of the receptacle through a compartment. This load will be applied by placing a bolster plate to the backside area of the receptacle and attaching it to one or more cables that are passed through drill holes added to the rear wall of the actual receptacle. In addition, the USPS may, at its discretion, order that production of the receptacle cease immediately, and that any existing inventory not be sold for receipt of U.S. mail. The master key for the United States Postal Service in Clarksville has been stolen. Recessed- or … Notification of such changes must be sent to the address in section 1.3. With the USPS Loyalty Program, small businesses can now earn credits for Priority Mail ® and … Type VII, Rear Loader (No Parcel Compartment) A family of mail receptacles in a single column configuration with a rear access cover design, a minimum of 3 and a maximum of 9 customer compartments, and 1 mail collection compartment. In any double master door design, when the master loading door with the Arrow lock traps, or locks the left master loading door, a push-out device shall not be required if the carrier can easily grasp and open the left door. Maintain Focus with this modal by pressing your space bar. The thickness, form, and mechanical and chemical properties of the material shall be adequate to meet the operational, structural, and performance requirements set forth in this standard. Girth in. The holder shall be of sufficient size to hold a name card of .75 inch by 2.50 inches or as large as space permits. Copies of the preceding document can be obtained from Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062-2096. 1.1 Scope This standard covers the design, testing, and acceptance of wall-mounted, centralized mail receptacles. 4.11 Security Test Receptacles shall be tested, as described below, for resistance to tampering and unauthorized entry through the use of tools such as screwdrivers, flat plates, knives, pry bars, vise grips, pliers, chisels, and punches for a period not to exceed 3 minutes for each feature tested. The cards shall be numbered (e.g., 1P, 2P, etc) to correspond with their respective parcel receptacles. The only people with access to a USPS arrow key would be the post office employees…. In addition, the instruction sheet shall carry a notice that the receptacle met all requirements of the Postal Service standard. 7.2.2.1.1 Health and Safety If the USPS determines that the noncompliance or nonconformity constitutes a danger to the health or safety of customers and/or letter carriers, the USPS may, at its discretion, immediately rescind approval of the unit. 6.1.3.4 Quality Policy Manual Manufacturer shall submit its quality policy manual to the address listed in section 1.3. Any parcel compartment provided as an integral part of a receptacle design shall have a 910 lock that is keyed differently than any customer compartment lock in the receptacle. The lock-mounting hole in the door shall be able to withstand 100 foot-pounds of torque applied in the plane of the door, preventing the lock from being turned in the door allowing unauthorized entry into the compartment. The overall height, width, and depth of any receptacle shall be such that all the applicable mounting requirements shall be met. 7.2.2.3 Second Written Notification The USPS shall respond to the manufacturer in writing, via Registered MailTM, no later than 30 calendar days after receipt of the corrected receptacle with a determination of whether the manufacturer’s submission is accepted or rejected and with specific reasons for the determination. 5.3.7 Documentation Retention All of the approved source’s documentation pertaining to the approved product shall be kept for a minimum of three (3) years after shipment of product. Choose the format that will make your offer compelling. Plus, you can schedule a USPS ® pickup from your home or office. 3.11.2 Parcel Keys and Tags Heavy-duty, rigid, clear plastic tags with card inserts containing instructions to the Postal Service customer on the use of the key, shall be furnished with each key for an individual parcel receptacle. HOME GETTING STARTED DOCS HELP CENTER SKETCH BUILDER. Type II, Front Loader A family of mail receptacles in a double column configuration with a double master door design, a minimum of 3 and a maximum of 16 customer compartments, 1 mail collection compartment with separate outgoing mail slot and Arrow lock door, and 1 or 2 parcel compartments. The holder or clasp shall be located on the frame above each compartment or inside of the compartment where the customer's name will be easily visible to the carrier when the box is opened for loading. The tags shall also have a swivel device for key ring mounting. 4.6 Abrasion Resistance The unit’s coating/finish shall be tested for resistance to abrasion in accordance with method A of ASTM D968. This door shall not be numbered or lettered. Arrows are a powerful addition to timeline presentations, conveying a journey and making it easier for the audience … These tests shall not allow access to the customer or parcel compartment. 3.5.1 Customer Compartment Doors Once opened, a customer door shall remain in the opened position until closed and locked. This door shall be designed to accommodate the mounting of the Arrow lock and the securing of a minimum-sized (3 inches high by 12 inches wide by 15 inches deep) compartment, which typically shall be used for retrieval of collection mail. 4.11.2 Customer Compartment Doors Gaps and seams around the perimeter of the customer compartment doors shall be tested using pry tools listed in 4.11 for a period not to exceed 3 minutes to ensure that access to the compartment cannot be gained. 5.3.1 Document Control Documents used in the manufacture of product shall be controlled. No two compartments in the same receptacle shall be keyed alike. Customized Direct Mail Enhance Your Business Marketing Mail. STD-4C or STANDARD-4C refers to a set of standards and regulations set by the United States Postal Service regarding the specifications of cluster mailbox units used in new construction. Finished or coated surfaces shall be smooth and uniform, and free from soft areas, stain, chips, crazing, and cracks. In addition, the Arrow lock compartment door will also be subjected to a 2-minute torch test using commonly available microtorch kits. The Arrow lock “captures” the 910 lock after its key has been inserted and the lock turned to allow the customer to remove their parcel. The carrier access shall not have pinch points or sharp edges. 3.3 Colors, Coatings and Finishes Exterior colors and finishes of the receptacles, in general, shall be optional with the manufacturer. In addition, no compartment size shall be offered as “approved” that is larger than any Postal Service-tested and approved size for that particular manufacturer. The plastic tags shall be 1-1/2 + 1/16 inches wide by 3 + 1/16 inches long by 3/16 (+1/16, -0) inches thick, and shall have an opening at one end for a key ring. USPS master, or “arrow,” keys allow access to things like apartment lobbies, communal mailboxes and more. Weight. The rate of sand flow shall be 2 liters of sand in 22 +3 seconds. These programs add customization, appeal, and clear calls to action. Usps master arrow key. The drawings will be stamped and identified as representing each unit. Figure 9 Rear Loader, Double Column (No Parcel Compartment) - Long Description The size, shape, and layout can highlight your product or service with crisp efficiency or engaging elegance. In addition, no compartment size shall be offered as “approved” that is larger than any Postal Service tested and approved size for that particular manufacturer. Click-N-Ship FAQ's. Copies of United States Postal Service specifications, standards and drawings may be obtained from USPS Delivery and Industrial Equipment CMC, Greensboro, NC 27498-0001. 3.12 Marking For front-loading designs, there must be two inscriptions centered on the carrier access door: "U.S. MAIL" in a minimum of .50 inch high letters and "APPROVED BY THE POSTMASTER GENERAL" in a minimum of .18 inch high letters. It is also valid for units made of plastic that employ metal hardware. The mounting technique and hardware selected shall allow the receptacle, when wall-mounted in accordance with the manufacturer’s instructions, to meet the pull requirements of section 4.11.9. Get started using USPS.com by shopping or shipping. Use Click-N-Ship ® service to pay for postage and print a shipping label from your printer or at a Post Office ™ location. The control process for documents shall ensure the following: 5.3.2 Supplier Oversight A documented process that ensures the following: 5.3.3 Inspection and Testing The approved source shall monitor and verify that product characteristics match approved design. Cate Cauguiran reports. The unit under test shall undergo a similar temperature test, as described above, at a temperature of 140 F. 4.8 Structural Rigidity Requirements Pull loads of the specified magnitudes (see table II) shall be slowly applied at any point of the specific item of the unit under test. 3.18 Fabrication and Assembly All components and parts shall be fabricated and assembled to be permanently square and rigid to preclude binding, warping, or misalignment, which may reduce or prevent proper equipment operation or maintenance or may result in a premature failure of any part or component. Figure 5 Rear Loader, Double Column - Long Description The receptacles shall be designed to allow wall mounting in accordance with the installation requirements as stipulated in this document and the applicable sections of the current Postal Operations Manual (POM) as referenced in section 2.2. Figure 11 Front Loader, Parcel Only (Master Door) - Long Description 3.9.1 Customer Compartment Identification Customer compartment doors shall be identified using either numbers or letters, optionally, in sequence from top to bottom. 7.2.2.2 Manufacturer’s Response In all cases of noncompliance or nonconformity other than those determined to constitute a danger to the health or safety of customers and/or letter carriers, the manufacturer shall confer with the USPS and shall submit one sample of a corrected receptacle to the USPS for approval no later than 45 calendar days after receipt of the notification described in 7.2.2.1. The depicted representations are only examples of possible compartment configurations. 3.11 Keys and Key Identification All compartment keys for locks in accordance with Locknuts shall be included for installing the Arrow lock. There used to be a FOIA request in the ether that described something called a Lock Assembly Machine which builds the locks. In particular, drawings should include overall unit with standard and optional compartment size information plus details on the design of such critical features as the carrier access, customer, parcel and master load door(s) designs, hinge designs, all lock-mounting techniques and cam engagements, material selections, the 3-point latching and handle designs, the wall mounting concept, and outgoing mail slot design. The lock and door shall remain closed and locked after each test. Direct any questions about this program to National Materials Customer Service at 800-332-0317, option 4, then option 5, or via email at materials.customerservice@usps.gov. The gauge must be capable of easy insertion and removal; and while inserted, allow for the door(s) to be completely closed without interference. Card insert lettering shall be legible and of sufficient size and contrast to be easily read. All front loading receptacles shall have fixed solid backs. Type VIII, Front Loader (No Parcel Compartment) A family of mail receptacles in a double column configuration with a double master door design, a minimum of 3 and a maximum of 19 customer compartments, and 1 mail collection compartment with separate outgoing mail slot and Arrow lock door. This notification shall include the specific reasons that the unit is noncompliant or out of conformance and shall be sent via Registered MailTM. Contact: Robet Bouvier. The manufacturer bears all responsibility for their unit(s) meeting these requirements and the USPS reserves the right to retest any and all units submitted including those which are available to the general public. The phrase “OUTGOING MAIL” shall be marked on the deposit slot shield in black, recessed lettering.

Baasha Of Israel, Custom Laptop Skins Uae, Art Laboe Radio Station Las Vegas, Bissell Vacuum Hose Extension, Christina Finds Out Owen Cheated, Spirited Midday Meal Crossword Clue, Best Bluetooth Transmitter For Bose Qc35 Ii, Principles Of Documentation Slideshare,